255-0009 - Miller Smith 250 Series Silverline High Purity Regulator, 0-350 PSI, CGA 580

Packaging: 1 per ea
$532.92/ea $350.24/1 per ea only $350.24/eaSave 34%

Usually ships within 3-5 business days

OVERVIEW

Rugged Reliability for Liquid Cylinders

Equip your operation with the Miller Smith 255-00-09 Silverline Regulator, a robust solution designed for the unique challenges of liquid cylinder gas delivery. This single-stage regulator is built to handle inlet pressures up to 3500 PSIG while delivering a steady, adjustable output of 0-350 PSIG. Its rear-entry CGA 580 connection is specifically oriented for direct mounting to liquid cylinders, eliminating the need for awkward adapters or strained hoses. Ideal for welding shops, industrial facilities, and laboratories utilizing bulk inert gases, this regulator combines heavy-duty construction with precision performance.

Built to Last in Industrial Environments

Durability is at the core of the Miller Smith 255-00-09. The unit is constructed from rugged brass bar stock and finished with a tough nickel plating on the body, bonnet, and gauges. This plating not only gives the regulator a professional appearance but also provides a hard-wearing shield against corrosion and atmospheric contaminants. The internal components are equally robust, featuring a large 1-7/8" stainless steel diaphragm. Unlike rubber or neoprene diaphragms that can become brittle over time, the stainless steel diaphragm offers extended service life and consistent performance, even in the demanding conditions of cryogenic gas applications.

Precision and Safety Features

Safety and accuracy are non-negotiable in gas regulation. The 255-00-09 incorporates Miller's proprietary Sure-Seat™ technology, which includes a filtered seat to trap debris and protect the regulator's internal mechanisms. This feature is essential for preventing creep and ensuring that the set pressure remains stable during operation. Additionally, the regulator includes a built-in capturable preset safety relief valve, adding an extra layer of protection for your downstream equipment. The large 2-1/2" gauges provide clear, instant readouts of tank and line pressure, ensuring your operators can monitor the system with confidence.

Versatile Application

While designed for liquid cylinders, this regulator is versatile enough for a range of high-purity gas handling tasks. It controls the delivery of gas (not liquid) from the cylinder, making it suitable for analytical instruments, laser systems, and specialized welding applications requiring pure argon or nitrogen. Invest in the Miller Smith 255-00-09 for a regulator that delivers consistent pressure, reduced maintenance costs, and long-term reliability.

Additional Information
Brand:Miller
Cga Fitting:CGA 580
Item:Regulator
Max Inlet:3500 PSI
Max Outlet:350 PSI
Used On Which Gas:Inert Gases, Argon or Nitrogen
Packaging Description:1-per-ea
Gas Type:Inert Gas, Specialty Gas, Argon, Nitrogen
Connection Type (CGA):CGA 580
Inlet/Outlet Pressure:Max Inlet: 3500 PSIG, Delivery: 0-350 PSIG
Gauge Type:2-1/2 in Single Scale
Body Material:Nickel Plated Brass Bar Stock
Diaphragm Material:Stainless Steel
Orientation:Rear Entry (Back Mount)
Series:250 Silverline

INCLUDED

  • 1 x Miller Smith 255-00-09 Silverline Regulator
  • 1 x Set of 2-1/2" Single Scale Gauges (Installed)
  • 1 x CGA 580 Rear Inlet Connection
  • 1 x 1/4" FNPT Outlet Connection
  • 1 x Owner's Manual/Warranty Information

APPLICATIONS

  • High purity gas handling and distribution
  • Analytical laboratories and research facilities
  • Liquid cylinder gas withdrawal (Argon, Nitrogen, Helium)
  • Bulk gas distribution systems
  • Laser cutting and welding gas supply
  • Industrial process control

FAQ

The Miller Smith 255-00-09 is rated for a maximum inlet pressure of 3500 PSIG.

No, this regulator is designed to control the delivery of gas from the gas use valve of a liquid cylinder. It is not designed to handle liquid directly.

The stainless steel diaphragm provides superior sensitivity for precise pressure control and offers excellent durability, especially in cryogenic applications where temperature fluctuations occur. It also prevents contamination of high-purity gases.

CGA 580 is the standard connection for inert gases such as Argon, Nitrogen, and Helium.

This regulator has a delivery pressure range of 0-350 PSIG.

The rear-entry (back mount) design is specifically engineered for liquid cylinders, allowing the regulator to mount cleanly without interfering with the cylinder's protective ring or other valves.

Sure-Seat is a filtered seat design by Miller Smith that prevents debris and contamination from entering the high-pressure seating area, significantly reducing repair costs and extending regulator life.

Yes, it comes equipped with two large 2-1/2 inch single scale gauges for monitoring inlet and delivery pressure.