OVERVIEW

Heavy-Duty Power for Pressure Testing

When your job requires more than just standard shielding gas flow, the Gentec 591N-1500-680 steps up to the plate. This isn't your average flowmeter; it is a high-pressure beast designed for welders, pipefitters, and HVAC technicians who need to perform serious pressure testing or system purging. With a delivery capacity of up to 1500 PSI, this regulator allows you to push Nitrogen, Argon, or Helium into systems to verify integrity before you lay a single bead or charge a system. The CGA-680 connection is specifically designed for high-pressure tanks, ensuring you can hook up to the heavy-duty cylinders required for intensive site work.

We know that gear on a job site takes a beating. That’s why the 591N series ditches the fragile rubber diaphragm found in light-duty regulators and replaces it with a solid brass piston. This piston design can handle the shock of opening a high-pressure valve without blowing out, giving you peace of mind every time you crack the cylinder. The solid brass body is machined, not cast, meaning it can survive the knocks, drops, and drags that happen in the back of a truck or on a busy fabrication floor. The gauges are housed in steel cases, adding another layer of protection against accidental impact.

Whether you are purging a long run of stainless pipe with Argon, pressure testing a new HVAC installation with Nitrogen, or charging shock absorbers, precision and safety are key. The Gentec 591N gives you smooth, controlled pressure adjustment thanks to its low-friction Delrin bushing. Don't risk your safety or your reputation with undersized equipment. Equip your rig with a regulator that matches the pressure of your work. The 591N-1500-680 is built to perform when the pressure is on.

Additional Information
Brand:Gentec
CGA Fitting:CGA 680
Item:Regulator
Used On Which Gas:Inert Gases, Argon or Nitrogen
Max Outlet:1500 PSI
Max Inlet:5500 PSI
Gas Type:Argon, Helium, Nitrogen
Regulator Type:Piston
Gauge Type:2-1/2" Steel Dual Scale
Body Material:Machined Brass
Filter Type:Sintered Bronze
Applications:High Pressure Testing, Accumulator Charging, Oil and Gas Industry
Packaging Description:1 of each
Used On Which Gas?:Argon or Nitrogen

INCLUDED

  • 1 x Gentec 591N Series High Pressure Regulator
  • 1 x Set of 2.5-inch Dual Scale Gauges (Inlet/Outlet)
  • 1 x CGA-680 Inlet Connection
  • 1 x Outlet Fitting (1/4" SAE Flare or similar standard)
  • 1 x Instructions/Safety Manual

APPLICATIONS

  • High Pressure Testing: Ideal for leak testing pipelines, HVAC systems, and pressure vessels using Nitrogen or other inert gases.
  • Accumulator Charging: Used to pressurize hydraulic accumulators to specific operational requirements.
  • System Purging: High-flow purging of large piping systems in petrochemical and refinery applications.
  • Aircraft Maintenance: Strut and tire inflation requiring high-pressure Nitrogen.
  • Laboratory & Research: Delivering high-pressure inert gas for catalytic reactions or process control.

FAQ

A piston regulator uses a solid metal piston to control pressure, whereas a diaphragm regulator uses a flexible rubber or metal disc. Piston regulators are generally more durable and better suited for high-pressure applications (both inlet and outlet) because they are less prone to rupturing under pressure spikes.

CGA-680 is a standardized cylinder connection fitting designated by the Compressed Gas Association. It is specifically designed for inert gases (like Argon, Nitrogen, and Helium) in high-pressure cylinders, typically ranging from 3001 to 5500 PSIG.

No. This regulator is designed and cleaned for inert gas service. Using it with Oxygen is dangerous due to the risk of adiabatic compression ignition, especially with the materials and lubricants used in inert gas equipment. Always use a regulator specifically rated and cleaned for Oxygen service (CGA-540 or similar).

The Gentec 591N-1500-680 is rated for a maximum delivery pressure of 1500 PSI. It is important to ensure that any downstream equipment (hoses, valves, tanks) is rated to handle this pressure.

Yes, absolutely. The high delivery pressure (1500 PSI) makes it excellent for pressure testing refrigeration lines and systems that require high-pressure Nitrogen to identify leaks.

Pressure is adjusted via the T-handle on the front of the regulator. Turning the handle clockwise increases the delivery pressure, while turning it counter-clockwise decreases it. Always adjust pressure while gas is flowing slightly for the most accurate setting.

Yes, this model typically comes with two 2-1/2 inch steel dual-scale gauges: one indicating the cylinder (inlet) pressure and one indicating the delivery (outlet) pressure.
Google Rating
4.9
Based on35reviews
×
js_loader